iulhk11-4301-6-airpax-iul-linked-toggle-circuit-breaker, iulhk11-4301-6-airpax-iul-linked-toggle-circuit-breaker, /circuit-breakers585
EN
Airpax IUL breaker with a linked toggle and threaded terminals. Six actual photos show the assembly, side markings and carton label.
Order IULHK11-4301-6 by the complete part number, not by the size of the housing or a number copied from one of the smaller side labels. This Airpax IUL circuit breaker is shown as a joined assembly with a visible linked toggle and threaded terminals. The gallery includes the part label, the molded Airpax side, the front handle, the separate side markings, the terminal end and the carton label. Use those views to identify what you are asking us to quote, then have the assembly reviewed against your equipment documentation.
Look at the front view first. The photographed linked toggle circuit breaker has two adjacent housing sections and a bar across the toggle area. That is an observation about the hardware you can see. The photograph does not prove how an internal fault on either side affects the other side. For a design that requires a specific trip or switching relationship, ask the responsible engineer to compare the exact device diagram with the approved drawing before accepting a replacement. A visual handle link is not enough to confirm internal operation.
Keep the assembly together when documenting it for a quotation. Instead of sending a close crop of one half, give purchasing an image that shows the handle link and both housings. On a service record for IULHK11-4301-6, capture which side is facing the photographer and note any differences from the approved spare. A record like that is more useful than two isolated pictures without context, especially when other units in the maintenance store use a similar black housing.
The side with the long part label identifies the unit as IULHK11-4301-6. In the gallery view that shows both smaller labels side by side, one side shows entries including SP and TV 20. The other side shows entries including I 15, V 80, a DC symbol, D 51 and TA 18.8. Those entries are transcribed as markings for identification. This listing does not interpret SP or TV, assign a voltage or current to the complete assembly, or claim an approved use for the Airpax IUL circuit breaker from those entries alone.
When capturing markings from your own unit, transcribe each side into a separate line in the maintenance request. Keep the field names or abbreviations with the values so that the person reviewing them can distinguish a current marking from a trip entry or another code. Do not average the values, combine them into a single rating, or substitute a value from a family data sheet. If the approval depends on the role of either side, request documentation for the exact Airpax IUL circuit breaker and verify it with the equipment owner.
The rear view shows threaded terminals and positions visibly numbered 1, 2, 3 and 4. For a comparison between the photographed unit and an installed linked toggle circuit breaker, capture the rear view and the handle view in the same orientation where practical. Identify any mounting or clearance feature that differs, including the direction the leads approach, the available depth and access to the nuts. The gallery helps you see where to compare. It is not a wiring diagram and does not establish terminal torque, thread size or wiring assignments.
When part drawings are available, use them for dimensions that cannot be measured from a photograph. Keep any existing lug, barrier or cover requirement on the comparison record, even if it does not appear in the product photographs. This matters when a spare must be installed without changes to the panel. The same external outline does not show whether an existing conductor, hardware stack or protective cover will fit a different version. Ask the reviewer to record any clearance issue that would require a mechanical change, rather than treating the replacement as a like for like purchase.
For each quote line, note what has been confirmed and what still needs approval. One useful distinction is whether the vendor confirmed the complete part number, or only identified a possible match from pictures. Before placing the order, resolve any question about the joined housings, the label on either side or the supplied hardware. If the quotation includes a proposed alternative, have it listed separately from the requested linked toggle circuit breaker.
No. The carton label is useful for checking the item reference, but it does not establish what is inside a particular shipment. Ask for the offered unit label when traceability matters, and compare the actual parts to your purchase documents at receipt. Printed quantities on cartons are not a statement of current availability.
No. For a linked toggle circuit breaker, verify the required mechanical fit and internal behavior separately. Have a qualified reviewer check the exact part documentation and approved equipment record before accepting a substitute with a different number.
Group the request by approved equipment part number. Send one label set per distinct configuration rather than treating a shared enclosure or current marking as proof of a match. Identify how many units are needed now and which quantities are for future service.
Use Request a Quote for IULHK11-4301-6. Include the required quantity and delivery destination, plus an existing unit photo or approved drawing if you need help identifying the exact assembly.
Airpax IUL breaker with a linked toggle and threaded terminals. Six actual photos show the assembly, side markings and carton label.
Explore premium ICs, sensors, and power controls to support your advanced technical requirements.