Your Trusted Partner in Electronics Supply Chain. Inquire Now!

Explore Our Latest Smart Electronics Collection.

jae-1-1rec4-41066-250-airpax-jae-250-a-dc-circuit-breaker, jae-1-1rec4-41066-250-airpax-jae-250-a-dc-circuit-breaker, /circuit-breakers585
Inquiry
Inquiry

JAE-1-1REC4-41066-250 Airpax JAE 250 A DC Circuit Breaker

Request a Quote
  • Overview

Overview

Use this listing when the approved parts record calls for JAE-1-1REC4-41066-250. This Airpax JAE circuit breaker is the 250 A version, not the similarly shaped version ending in 100. The useful buying decision is whether the offered breaker matches the equipment file without reopening the panel design. Start with the label, then verify how the original device is mounted and how the control circuit uses the auxiliary switch. A matching black housing or shared family name does not settle those questions.

Make the exact match decision at the parts desk

Put the entire JAE-1-1REC4-41066-250 identifier in the manufacturer part number field of the request. If the maintenance order only says 250 A DC circuit breaker, attach the approved drawing or a clear label photograph. Record which characters have been read from the actual part and which came from the equipment record. If the two references disagree, do not correct the difference by assumption. Return the record to the person who controls the equipment configuration and ask for written disposition.

A useful inspection pair is the device label and the handle face. The pictured handle is marked 250; the label carries the full part number. Use both before releasing a pick from stock. A photograph from a seller or a carton label can establish what was pictured, but cannot prove the contents of every carton. For a multiunit order, define what identity check is required per unit and how any mismatch will be segregated. Treat the 100 and 250 endings as separate configurations in the purchasing system.

Separate nameplate evidence from design approval

The photographed Airpax JAE circuit breaker has a 160 V maximum marking with the DC symbol. It also has a separate trip amps entry and delay code. Those entries answer different questions: do not treat a trip threshold as the continuous current rating or a delay code as a fixed time. A qualified reviewer should use the manufacturer data and approved device configuration to check interruption requirements at the actual operating voltage. Do not carry series ratings from a different configuration into a quote for this 250 A DC circuit breaker.

In a cabinet project, the available fault current, approved protection arrangement and physical position are application inputs, not values that a reseller can establish from a product photo. Write those requirements into the buyer's equipment file rather than assuming that a label value makes the breaker suitable. In particular, the device label identifies vertical surface use only and limits general use. If the proposed location or use differs from the approved installation, ask the equipment maker or the responsible engineer to approve the change before purchase.

Check the monitoring circuit as a separate interface

A position or alarm circuit may depend on the auxiliary switch even when the main power path looks unchanged. On the pictured device, the auxiliary markings are separate from the DC power markings. Do not use the auxiliary switch's AC marking to specify the main circuit. For an Airpax JAE circuit breaker being replaced during an outage, record which auxiliary behavior the approved schematic requires. Ask for the exact configuration drawing when that behavior affects the equipment acceptance test.

Have the review distinguish three decisions: the device fits the panel, the main protection is approved and the auxiliary function matches the control circuit. The photos can help compare the enclosure and actuator, but they do not establish wiring, terminal torque or the contact state. Where the old device cannot be compared directly, the approved installation drawing is a better reference than a family photograph. Keep any open item visible in the quote instead of silently assuming equivalence.

Document which spare belongs to which cabinet

If several cabinets are serviced during one shutdown, use the cabinet or feeder identifier in the purchase request as well as the breaker number. Give the receiving team a reference image that shows both the handle and the device label. In the maintenance store, do not put a 250 A DC circuit breaker into the bin for the 100 variant, even if the same mounting envelope is recorded. Keep the packing slip and the checked part reference with the spare. If an engineering exception is granted for a different configuration, file that decision with the equipment record rather than using it to relabel the remaining stock.

What to specify on the RFQ

  • Use JAE-1-1REC4-41066-250 and say whether the request is exact match only. Quote alternates on a separate line.
  • Identify whether you need one outage spare, inspection samples or a replenishment quantity. Provide the ship-to destination and target receipt date.
  • State what lot photographs, marking checks or packaging information are required before the order is released.
  • For the 250 A DC circuit breaker, include the approved equipment part reference and any required auxiliary switch and vertical mounting documentation.

Before accepting the quote, check that the line item repeats the full model and distinguishes the proposed lot from photographs used only for identification. Confirm the shipment quantity, condition and any inspection evidence in writing. The carton photos on this page are not a statement of available stock or a promise that all cartons carry the same lot. Ask for clarification if the ordering reference, delivered markings or packaging requirements are not explicit.

Buyer questions for the 250 A variant

Can I use the model ending in 100 if it fits the same panel?

Do not assume that. The suffix is part of the approved configuration. An alternate for this Airpax JAE circuit breaker needs a separate engineering and purchase decision.

What if the carton and handle markings disagree?

Keep the parts apart and ask for legible photos of the device label and handle on the offered unit. Do not accept a substitution against the carton label alone.

How do I request a sample before buying a larger lot?

Use Request a Quote for JAE-1-1REC4-41066-250, list the sample and expected balance separately and state what the sample must demonstrate. Ask for an exact match and the offered lot details if your inspection plan depends on them.

JAE-1-1REC4-41066-250 Airpax JAE 250 A DC Circuit Breaker

Request a Quote
{"cf_related_products":{"field_type":"product","type":"array","value":[],"config":""}}

Related Products

Explore premium ICs, sensors, and power controls to support your advanced technical requirements.

jae 1 1rec4 41066 250 airpax jae 250 a dc circuit breaker-2

Get a Free Quote

Our representative will contact you soon.
Email
WhatsApp / Mobile Phone
Company Name
Part Number
Message
0/1000
Attachment
Please upload at least an attachment (Optional)
Upload up to 5 files (maximum 30 MB). Supported formats: JPG, JPEG, PNG, PDF, DOC, DOCX, XLS, XLSX, CSV, TXT, STP, STEP, IGS, X_T, DXF, PRT, SLDPRT, SAT, RAR, ZIP.